{"product_id":"victron-lynx-shunt-ve-can-m10-1000a","title":"Victron Lynx Shunt VE.Can M10 1000A","description":"\u003cp data-start=\"261\" data-end=\"406\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Victron Lynx Shunt VE.Can M10 combines high-current DC distribution, battery monitoring and a main system fuse holder within one Lynx module.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"408\" data-end=\"772\"\u003eIts integrated 1000A shunt measures battery voltage, current, state of charge and related system data, which can be viewed through a compatible GX device and the VRM portal. The M10 version supports 12V, 24V and 48V systems and includes a removable busbar link, allowing the main fuse to be installed externally when required. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"774\" data-end=\"790\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"792\" data-end=\"984\"\u003e\n\u003cli data-section-id=\"cdrkjr\" data-start=\"792\" data-end=\"835\"\u003eIntegrated 1000A battery-monitoring shunt\u003c\/li\u003e\n\u003cli data-section-id=\"jddzbt\" data-start=\"836\" data-end=\"869\"\u003eHolder for the main system fuse\u003c\/li\u003e\n\u003cli data-section-id=\"v6q4w9\" data-start=\"870\" data-end=\"919\"\u003eVE.Can communication with compatible GX devices\u003c\/li\u003e\n\u003cli data-section-id=\"nfbv57\" data-start=\"920\" data-end=\"946\"\u003eProgrammable alarm relay\u003c\/li\u003e\n\u003cli data-section-id=\"ke4es0\" data-start=\"947\" data-end=\"984\"\u003eSupplied battery-temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"986\" data-end=\"1004\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1006\" data-end=\"1341\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1006\" data-end=\"1032\"\u003e\n\u003ctr data-start=\"1006\" data-end=\"1032\"\u003e\n\u003cth data-start=\"1006\" data-end=\"1022\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1022\" data-end=\"1032\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1043\" data-end=\"1341\"\u003e\n\u003ctr data-start=\"1043\" data-end=\"1072\"\u003e\n\u003ctd data-start=\"1043\" data-end=\"1060\" data-col-size=\"sm\"\u003eSupply voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1060\" data-end=\"1072\"\u003e9–70V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1073\" data-end=\"1112\"\u003e\n\u003ctd data-start=\"1073\" data-end=\"1093\" data-col-size=\"sm\"\u003eSupported systems\u003c\/td\u003e\n\u003ctd data-start=\"1093\" data-end=\"1112\" data-col-size=\"sm\"\u003e12V, 24V or 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1113\" data-end=\"1150\"\u003e\n\u003ctd data-start=\"1113\" data-end=\"1141\" data-col-size=\"sm\"\u003eContinuous current rating\u003c\/td\u003e\n\u003ctd data-start=\"1141\" data-end=\"1150\" data-col-size=\"sm\"\u003e1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1151\" data-end=\"1184\"\u003e\n\u003ctd data-start=\"1151\" data-end=\"1177\" data-col-size=\"sm\"\u003eLynx busbar connections\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1177\" data-end=\"1184\"\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1185\" data-end=\"1223\"\u003e\n\u003ctd data-start=\"1185\" data-end=\"1217\" data-col-size=\"sm\"\u003eFuse or fuse-dummy connection\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1217\" data-end=\"1223\"\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1224\" data-end=\"1259\"\u003e\n\u003ctd data-start=\"1224\" data-end=\"1240\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1240\" data-end=\"1259\"\u003eVE.Can via RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1260\" data-end=\"1288\"\u003e\n\u003ctd data-start=\"1260\" data-end=\"1280\" data-col-size=\"sm\"\u003eProtection rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1280\" data-end=\"1288\"\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1289\" data-end=\"1322\"\u003e\n\u003ctd data-start=\"1289\" data-end=\"1302\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1302\" data-end=\"1322\"\u003e190 × 180 × 80mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1323\" data-end=\"1341\"\u003e\n\u003ctd data-start=\"1323\" data-end=\"1332\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1332\" data-end=\"1341\"\u003e1.4kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"1343\" data-end=\"1425\"\u003eThe unit has no reverse-polarity protection. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"purqi0\" data-start=\"1427\" data-end=\"1444\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp data-start=\"1446\" data-end=\"1665\"\u003eDesigned for M10 versions of the Victron Lynx distribution system. Battery-monitor data, configuration and remote monitoring require a compatible GX device connected through VE.Can. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"6zii9o\" data-start=\"1667\" data-end=\"1692\"\u003eFitment \/ Wiring Note\u003c\/h3\u003e\n\u003cp data-start=\"1694\" data-end=\"1975\"\u003eInstall the Lynx Shunt between the battery side and the DC system side so all charge and discharge current passes through the shunt. The main fuse, cabling and protection must be selected for the complete installation. Work must only be completed with the DC system fully isolated.\u003c\/p\u003e\n\u003ch3 data-section-id=\"14lzghq\" data-start=\"1977\" data-end=\"1996\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul data-start=\"1998\" data-end=\"2164\"\u003e\n\u003cli data-section-id=\"t9y3tl\" data-start=\"1998\" data-end=\"2029\"\u003eVictron Lynx Shunt VE.Can M10\u003c\/li\u003e\n\u003cli data-section-id=\"1mvdnb2\" data-start=\"2030\" data-end=\"2059\"\u003eTwo VE.Can RJ45 terminators\u003c\/li\u003e\n\u003cli data-section-id=\"iyf0he\" data-start=\"2060\" data-end=\"2088\"\u003eBattery-temperature sensor\u003c\/li\u003e\n\u003cli data-section-id=\"1t7sr99\" data-start=\"2089\" data-end=\"2113\"\u003eFuse-dummy busbar link\u003c\/li\u003e\n\u003cli data-section-id=\"1fvq1ej\" data-start=\"2114\" data-end=\"2164\"\u003eConnection hardware and installation information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2166\" data-end=\"2245\"\u003e\u003cstrong data-start=\"2166\" data-end=\"2207\"\u003eThe main system fuse is not included\u003c\/strong\u003e\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":54323482001749,"sku":"VLYNXSH-M10","price":289.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0944\/8004\/0277\/files\/1761047878_67020400.png?v=1783517341","url":"https:\/\/relivecampers.co.uk\/products\/victron-lynx-shunt-ve-can-m10-1000a","provider":"Relive Campers LTD","version":"1.0","type":"link"}