{"product_id":"victron-lynx-power-in-1000a-dc-busbar","title":"Victron Lynx Power In 1000A DC Busbar – M8 or M10","description":"\u003cp data-start=\"416\" data-end=\"570\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Victron Lynx Power In is a modular 1000A DC busbar for connecting batteries, chargers and high-current DC equipment within a Lynx distribution system.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"572\" data-end=\"917\"\u003eIt contains positive and negative tinned-copper busbars with four connection points and a ground connection. Choose the M8 or M10 version to match the other Lynx modules in the installation. The Power In has no integrated fuse positions, so each connected circuit requires suitable external fuse protection. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"919\" data-end=\"935\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"937\" data-end=\"1173\"\u003e\n\u003cli data-section-id=\"z89uzw\" data-start=\"937\" data-end=\"988\"\u003eFour connections for batteries, loads or chargers\u003c\/li\u003e\n\u003cli data-section-id=\"1yzv3tz\" data-start=\"989\" data-end=\"1034\"\u003ePositive and negative tinned-copper busbars\u003c\/li\u003e\n\u003cli data-section-id=\"mt0qmj\" data-start=\"1035\" data-end=\"1068\"\u003e1000A continuous current rating\u003c\/li\u003e\n\u003cli data-section-id=\"1v00wz\" data-start=\"1069\" data-end=\"1123\"\u003eAvailable with M8 or M10 Lynx interconnection joints\u003c\/li\u003e\n\u003cli data-section-id=\"eox42l\" data-start=\"1124\" data-end=\"1173\"\u003eIntegrates with compatible Victron Lynx modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1175\" data-end=\"1193\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1195\" data-end=\"1552\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1195\" data-end=\"1221\"\u003e\n\u003ctr data-start=\"1195\" data-end=\"1221\"\u003e\n\u003cth data-start=\"1195\" data-end=\"1211\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1211\" data-end=\"1221\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1232\" data-end=\"1552\"\u003e\n\u003ctr data-start=\"1232\" data-end=\"1260\"\u003e\n\u003ctd data-start=\"1232\" data-end=\"1248\" data-col-size=\"sm\"\u003eVoltage range\u003c\/td\u003e\n\u003ctd data-start=\"1248\" data-end=\"1260\" data-col-size=\"sm\"\u003e9–60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1261\" data-end=\"1300\"\u003e\n\u003ctd data-start=\"1261\" data-end=\"1281\" data-col-size=\"sm\"\u003eSupported systems\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1281\" data-end=\"1300\"\u003e12V, 24V or 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1301\" data-end=\"1338\"\u003e\n\u003ctd data-start=\"1301\" data-end=\"1329\" data-col-size=\"sm\"\u003eContinuous current rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1329\" data-end=\"1338\"\u003e1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1339\" data-end=\"1397\"\u003e\n\u003ctd data-start=\"1339\" data-end=\"1362\" data-col-size=\"sm\"\u003eLynx interconnection\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1362\" data-end=\"1397\"\u003eM8 or M10, depending on variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1398\" data-end=\"1434\"\u003e\n\u003ctd data-start=\"1398\" data-end=\"1428\" data-col-size=\"sm\"\u003eEquipment cable connections\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1428\" data-end=\"1434\"\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1435\" data-end=\"1470\"\u003e\n\u003ctd data-start=\"1435\" data-end=\"1453\" data-col-size=\"sm\"\u003eBusbar material\u003c\/td\u003e\n\u003ctd data-start=\"1453\" data-end=\"1470\" data-col-size=\"sm\"\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1471\" data-end=\"1499\"\u003e\n\u003ctd data-start=\"1471\" data-end=\"1491\" data-col-size=\"sm\"\u003eProtection rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1491\" data-end=\"1499\"\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1500\" data-end=\"1533\"\u003e\n\u003ctd data-start=\"1500\" data-end=\"1513\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1513\" data-end=\"1533\"\u003e290 × 170 × 80mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1534\" data-end=\"1552\"\u003e\n\u003ctd data-start=\"1534\" data-end=\"1543\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1543\" data-end=\"1552\"\u003e2.1kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"1554\" data-end=\"1591\"\u003e \u003c\/p\u003e\n\u003ch3 data-section-id=\"purqi0\" data-start=\"1593\" data-end=\"1610\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp data-start=\"1612\" data-end=\"1800\"\u003eM8 modules connect to other M8 Lynx modules, while M10 modules connect to M10 versions. M8 and M10 Lynx modules cannot be connected directly together. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"6zii9o\" data-start=\"1802\" data-end=\"1827\"\u003eFitment \/ Wiring Note\u003c\/h3\u003e\n\u003cp data-start=\"1829\" data-end=\"2068\"\u003eAll connected cables require M8 cable lugs, including on the M10 version. Cable capacity and external fuse protection must suit each circuit, and the busbars must be fully isolated before installation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"14lzghq\" data-start=\"2070\" data-end=\"2089\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul data-start=\"2091\" data-end=\"2148\"\u003e\n\u003cli data-section-id=\"1vke75t\" data-start=\"2091\" data-end=\"2148\"\u003eVictron Lynx Power In in the selected M8 or M10 version\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"M8 Terminals","offer_id":54323481903445,"sku":"VLYNX-PI","price":119.95,"currency_code":"GBP","in_stock":true},{"title":"M10 Terminals","offer_id":54323481936213,"sku":"VLYNXPI-M10","price":119.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0944\/8004\/0277\/files\/1685634051_10590900.png?v=1783517339","url":"https:\/\/relivecampers.co.uk\/products\/victron-lynx-power-in-1000a-dc-busbar","provider":"Relive Campers LTD","version":"1.0","type":"link"}