{"product_id":"victron-lynx-distributor-m10-1000a","title":"Victron Lynx Distributor M10 1000A DC Distribution Module","description":"\u003cp data-start=\"352\" data-end=\"524\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Victron Lynx Distributor M10 provides organised high-current DC distribution through positive and negative busbars, with connections for four separately fused circuits.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"526\" data-end=\"874\"\u003eEach circuit accepts a MEGA fuse and has an individual fuse-status LED. When connected to a compatible Lynx Smart BMS, fuse condition and operational status can also be monitored through the wider Victron system. The unit supports 12V, 24V and 48V installations and is rated for up to 1000A continuous current. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"876\" data-end=\"892\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"894\" data-end=\"1104\"\u003e\n\u003cli data-section-id=\"10ce3jt\" data-start=\"894\" data-end=\"934\"\u003eFour individually fused DC connections\u003c\/li\u003e\n\u003cli data-section-id=\"1yzv3tz\" data-start=\"935\" data-end=\"980\"\u003ePositive and negative tinned-copper busbars\u003c\/li\u003e\n\u003cli data-section-id=\"1mukpt0\" data-start=\"981\" data-end=\"1020\"\u003eIndividual LED fuse-status indication\u003c\/li\u003e\n\u003cli data-section-id=\"mt0qmj\" data-start=\"1021\" data-end=\"1054\"\u003e1000A continuous current rating\u003c\/li\u003e\n\u003cli data-section-id=\"o488bm\" data-start=\"1055\" data-end=\"1104\"\u003eIntegrates with the modular Victron Lynx system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1106\" data-end=\"1124\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1126\" data-end=\"1442\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1126\" data-end=\"1152\"\u003e\n\u003ctr data-start=\"1126\" data-end=\"1152\"\u003e\n\u003cth data-start=\"1126\" data-end=\"1142\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1142\" data-end=\"1152\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1163\" data-end=\"1442\"\u003e\n\u003ctr data-start=\"1163\" data-end=\"1191\"\u003e\n\u003ctd data-start=\"1163\" data-end=\"1179\" data-col-size=\"sm\"\u003eVoltage range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1179\" data-end=\"1191\"\u003e9–60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1192\" data-end=\"1231\"\u003e\n\u003ctd data-start=\"1192\" data-end=\"1212\" data-col-size=\"sm\"\u003eSupported systems\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1212\" data-end=\"1231\"\u003e12V, 24V or 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1232\" data-end=\"1262\"\u003e\n\u003ctd data-start=\"1232\" data-end=\"1253\" data-col-size=\"sm\"\u003eContinuous current\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1253\" data-end=\"1262\"\u003e1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1263\" data-end=\"1297\"\u003e\n\u003ctd data-start=\"1263\" data-end=\"1290\" data-col-size=\"sm\"\u003eInter-module connections\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1290\" data-end=\"1297\"\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1298\" data-end=\"1333\"\u003e\n\u003ctd data-start=\"1298\" data-end=\"1327\" data-col-size=\"sm\"\u003eCable and fuse connections\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1327\" data-end=\"1333\"\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1334\" data-end=\"1360\"\u003e\n\u003ctd data-start=\"1334\" data-end=\"1346\" data-col-size=\"sm\"\u003eFuse type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1346\" data-end=\"1360\"\u003eMEGA fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1361\" data-end=\"1389\"\u003e\n\u003ctd data-start=\"1361\" data-end=\"1381\" data-col-size=\"sm\"\u003eProtection rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1381\" data-end=\"1389\"\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1390\" data-end=\"1423\"\u003e\n\u003ctd data-start=\"1390\" data-end=\"1403\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"1403\" data-end=\"1423\" data-col-size=\"sm\"\u003e290 × 170 × 80mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1424\" data-end=\"1442\"\u003e\n\u003ctd data-start=\"1424\" data-end=\"1433\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"1433\" data-end=\"1442\" data-col-size=\"sm\"\u003e2.2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"1444\" data-end=\"1636\"\u003eThe Lynx Distributor consumes up to 100mA with all LEDs illuminated and is powered through its RJ10 connection from a Lynx Shunt VE.Can or Lynx Smart BMS. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"purqi0\" data-start=\"1638\" data-end=\"1655\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp data-start=\"1657\" data-end=\"1734\"\u003eDesigned for M10 versions of the modular Victron Lynx DC distribution system.\u003c\/p\u003e\n\u003cp data-start=\"1736\" data-end=\"1954\"\u003eFuse-status data can be communicated to a Lynx Smart BMS. A Lynx Shunt VE.Can can power the fuse-monitoring electronics, but does not receive fuse-status data from the Distributor. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"6zii9o\" data-start=\"1956\" data-end=\"1981\"\u003eFitment \/ Wiring Note\u003c\/h3\u003e\n\u003cp data-start=\"1983\" data-end=\"2274\"\u003eSelect each MEGA fuse and cable size to suit its connected circuit. For 12V and 24V systems, Victron specifies 36V-rated MEGA fuses; 48V installations require 58V-rated MEGA fuses. Installation should only be carried out with the busbars fully isolated. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"14lzghq\" data-start=\"2276\" data-end=\"2295\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul data-start=\"2297\" data-end=\"2369\"\u003e\n\u003cli data-section-id=\"vqb6sz\" data-start=\"2297\" data-end=\"2327\"\u003eVictron Lynx Distributor M10\u003c\/li\u003e\n\u003cli data-section-id=\"75w4yu\" data-start=\"2328\" data-end=\"2369\"\u003e40cm RJ10 power and communication cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2371\" data-end=\"2474\"\u003e\u003cstrong data-start=\"2371\" data-end=\"2436\"\u003eMEGA fuses are not included and must be purchased separately.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":54323283263829,"sku":"VLYNX-M10","price":164.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0944\/8004\/0277\/files\/1755190546_61792000.png?v=1783517338","url":"https:\/\/relivecampers.co.uk\/products\/victron-lynx-distributor-m10-1000a","provider":"Relive Campers LTD","version":"1.0","type":"link"}