{"product_id":"victron-lynx-class-t-power-in-m10-1000a","title":"Victron Lynx Class-T Power In M10 1000A DC Busbar","description":"\u003cp data-start=\"371\" data-end=\"527\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Victron Lynx Class-T Power In provides a compact fused connection point for up to two lithium battery strings within an M10 Lynx DC distribution system.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"529\" data-end=\"892\" class=\"\"\u003eIt contains positive and negative tinned-copper busbars, two Class-T fuse positions and a system ground connection. Multiple modules can be combined when additional battery connections are required. The Class-T fuses must be selected to suit the connected batteries, cables and expected current, and are purchased separately. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"894\" data-end=\"910\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"912\" data-end=\"1124\"\u003e\n\u003cli data-section-id=\"8rlusw\" data-start=\"912\" data-end=\"955\"\u003eConnections for two fused battery strings\u003c\/li\u003e\n\u003cli data-section-id=\"1yzv3tz\" data-start=\"956\" data-end=\"1001\"\u003ePositive and negative tinned-copper busbars\u003c\/li\u003e\n\u003cli data-section-id=\"1lx8rxz\" data-start=\"1002\" data-end=\"1034\"\u003e1000A continuous busbar rating\u003c\/li\u003e\n\u003cli data-section-id=\"xgd35a\" data-start=\"1035\" data-end=\"1078\"\u003eM10 DC and Lynx interconnection terminals\u003c\/li\u003e\n\u003cli data-section-id=\"1b641ze\" data-start=\"1079\" data-end=\"1124\"\u003eIntegrates with compatible M10 Lynx modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1126\" data-end=\"1144\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1146\" data-end=\"1575\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1146\" data-end=\"1172\"\u003e\n\u003ctr data-start=\"1146\" data-end=\"1172\"\u003e\n\u003cth data-start=\"1146\" data-end=\"1162\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1162\" data-end=\"1172\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1183\" data-end=\"1575\"\u003e\n\u003ctr data-start=\"1183\" data-end=\"1211\"\u003e\n\u003ctd data-start=\"1183\" data-end=\"1199\" data-col-size=\"sm\"\u003eVoltage range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1199\" data-end=\"1211\"\u003e9–60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1212\" data-end=\"1260\"\u003e\n\u003ctd data-start=\"1212\" data-end=\"1240\" data-col-size=\"sm\"\u003eSupported system voltages\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1240\" data-end=\"1260\"\u003e12V, 24V and 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1261\" data-end=\"1305\"\u003e\n\u003ctd data-start=\"1261\" data-end=\"1285\" data-col-size=\"sm\"\u003eBusbar current rating\u003c\/td\u003e\n\u003ctd data-start=\"1285\" data-end=\"1305\" data-col-size=\"sm\"\u003e1000A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1306\" data-end=\"1336\"\u003e\n\u003ctd data-start=\"1306\" data-end=\"1331\" data-col-size=\"sm\"\u003eClass-T fuse positions\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1331\" data-end=\"1336\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1337\" data-end=\"1372\"\u003e\n\u003ctd data-start=\"1337\" data-end=\"1365\" data-col-size=\"sm\"\u003eDC and busbar connections\u003c\/td\u003e\n\u003ctd data-start=\"1365\" data-end=\"1372\" data-col-size=\"sm\"\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1373\" data-end=\"1405\"\u003e\n\u003ctd data-start=\"1373\" data-end=\"1392\" data-col-size=\"sm\"\u003eFuse connections\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1392\" data-end=\"1405\"\u003e3\/8-inch*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1406\" data-end=\"1457\"\u003e\n\u003ctd data-start=\"1406\" data-end=\"1431\" data-col-size=\"sm\"\u003eMaximum cable lug size\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1431\" data-end=\"1457\"\u003eUp to 120mm² \/ 4\/0 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1458\" data-end=\"1493\"\u003e\n\u003ctd data-start=\"1458\" data-end=\"1476\" data-col-size=\"sm\"\u003eBusbar material\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1476\" data-end=\"1493\"\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1494\" data-end=\"1522\"\u003e\n\u003ctd data-start=\"1494\" data-end=\"1515\" data-col-size=\"sm\"\u003eEnclosure material\u003c\/td\u003e\n\u003ctd data-start=\"1515\" data-end=\"1522\" data-col-size=\"sm\"\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1523\" data-end=\"1556\"\u003e\n\u003ctd data-start=\"1523\" data-end=\"1536\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"1536\" data-end=\"1556\" data-col-size=\"sm\"\u003e279 × 169 × 97mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1557\" data-end=\"1575\"\u003e\n\u003ctd data-start=\"1557\" data-end=\"1566\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"1566\" data-end=\"1575\" data-col-size=\"sm\"\u003e2.1kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"1577\" data-end=\"1725\"\u003e*Some later units identified by the serial-number format described in Victron’s manual use M10 fuse hardware. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"purqi0\" data-start=\"1727\" data-end=\"1744\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp data-start=\"1746\" data-end=\"1903\"\u003eDesigned for Victron’s \u003cstrong data-start=\"1769\" data-end=\"1801\"\u003eM10 Lynx distribution system\u003c\/strong\u003e. M10 and M8 Lynx modules cannot be connected directly together. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"6zii9o\" data-start=\"1905\" data-end=\"1930\"\u003eFitment \/ Wiring Note\u003c\/h3\u003e\n\u003cp data-start=\"1932\" data-end=\"2236\"\u003eClass-T fuses, cables and terminals must be selected for the connected battery and circuit. All DC cables require M10 lugs, and Victron specifies a 33Nm tightening torque for the M10 connections. Installation must be completed with the battery supply fully isolated. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"14lzghq\" data-start=\"2238\" data-end=\"2257\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul data-start=\"2259\" data-end=\"2314\"\u003e\n\u003cli data-section-id=\"vfozbn\" data-start=\"2259\" data-end=\"2294\"\u003eVictron Lynx Class-T Power In M10\u003c\/li\u003e\n\u003cli data-section-id=\"bjqaxe\" data-start=\"2295\" data-end=\"2314\"\u003eTerminal hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2316\" data-end=\"2351\"\u003e\u003cstrong data-start=\"2316\" data-end=\"2351\"\u003eClass-T fuses are not included.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":54323481706837,"sku":"VLYNXCTPI-M10","price":149.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0944\/8004\/0277\/files\/1761050177_53929600.png?v=1783517336","url":"https:\/\/relivecampers.co.uk\/products\/victron-lynx-class-t-power-in-m10-1000a","provider":"Relive Campers LTD","version":"1.0","type":"link"}