{"product_id":"victron-batteryprotect-12-24v","title":"Victron BatteryProtect 12\/24V Low-Voltage Disconnect – 65A to 220A","description":"\u003cp data-start=\"327\" data-end=\"506\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Victron BatteryProtect 12\/24V disconnects non-essential DC loads before the battery becomes excessively discharged, helping protect the battery and preserve starting capacity.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"508\" data-end=\"886\"\u003eIt automatically detects 12V or 24V systems during initial setup and offers selectable disconnect and reconnect voltage thresholds. The unit can also be controlled remotely or by a compatible external BMS in lithium installations. Choose the 65A, 100A or 220A model according to the maximum continuous current of the connected load circuit. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"888\" data-end=\"904\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"906\" data-end=\"1128\"\u003e\n\u003cli data-section-id=\"1olz3i1\" data-start=\"906\" data-end=\"954\"\u003eProtects batteries against excessive discharge\u003c\/li\u003e\n\u003cli data-section-id=\"h954o7\" data-start=\"955\" data-end=\"994\"\u003eAutomatic 12V or 24V system detection\u003c\/li\u003e\n\u003cli data-section-id=\"1trottp\" data-start=\"995\" data-end=\"1045\"\u003eProgrammable disconnect and reconnect thresholds\u003c\/li\u003e\n\u003cli data-section-id=\"snjsp6\" data-start=\"1046\" data-end=\"1069\"\u003eRemote on\/off control\u003c\/li\u003e\n\u003cli data-section-id=\"60hoex\" data-start=\"1070\" data-end=\"1128\"\u003eExternal BMS control option for suitable lithium systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1130\" data-end=\"1148\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1150\" data-end=\"1355\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1150\" data-end=\"1208\"\u003e\n\u003ctr data-start=\"1150\" data-end=\"1208\"\u003e\n\u003cth data-start=\"1150\" data-end=\"1160\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eVariant\u003c\/th\u003e\n\u003cth data-start=\"1160\" data-end=\"1181\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eContinuous current\u003c\/th\u003e\n\u003cth data-start=\"1181\" data-end=\"1196\" data-col-size=\"sm\" class=\"last:pe-10\"\u003ePeak current\u003c\/th\u003e\n\u003cth data-start=\"1196\" data-end=\"1208\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eTerminal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1229\" data-end=\"1355\"\u003e\n\u003ctr data-start=\"1229\" data-end=\"1269\"\u003e\n\u003ctd data-start=\"1229\" data-end=\"1235\" data-col-size=\"sm\"\u003e65A\u003c\/td\u003e\n\u003ctd data-start=\"1235\" data-end=\"1241\" data-col-size=\"sm\"\u003e65A\u003c\/td\u003e\n\u003ctd data-start=\"1241\" data-end=\"1263\" data-col-size=\"sm\"\u003e250A for 30 seconds\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1263\" data-end=\"1269\"\u003eM6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1270\" data-end=\"1312\"\u003e\n\u003ctd data-start=\"1270\" data-end=\"1277\" data-col-size=\"sm\"\u003e100A\u003c\/td\u003e\n\u003ctd data-start=\"1277\" data-end=\"1284\" data-col-size=\"sm\"\u003e100A\u003c\/td\u003e\n\u003ctd data-start=\"1284\" data-end=\"1306\" data-col-size=\"sm\"\u003e600A for 30 seconds\u003c\/td\u003e\n\u003ctd data-start=\"1306\" data-end=\"1312\" data-col-size=\"sm\"\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1313\" data-end=\"1355\"\u003e\n\u003ctd data-start=\"1313\" data-end=\"1320\" data-col-size=\"sm\"\u003e220A\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1320\" data-end=\"1327\"\u003e220A\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1327\" data-end=\"1349\"\u003e600A for 30 seconds\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1349\" data-end=\"1355\"\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1357\" data-end=\"1660\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1357\" data-end=\"1390\"\u003e\n\u003ctr data-start=\"1357\" data-end=\"1390\"\u003e\n\u003cth data-start=\"1357\" data-end=\"1380\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eShared specification\u003c\/th\u003e\n\u003cth data-start=\"1380\" data-end=\"1390\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1401\" data-end=\"1660\"\u003e\n\u003ctr data-start=\"1401\" data-end=\"1433\"\u003e\n\u003ctd data-start=\"1401\" data-end=\"1421\" data-col-size=\"sm\"\u003eOperating voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1421\" data-end=\"1433\"\u003e6–35V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1434\" data-end=\"1493\"\u003e\n\u003ctd data-start=\"1434\" data-end=\"1456\" data-col-size=\"sm\"\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1456\" data-end=\"1493\"\u003e1.5mA active \/ 0.6mA disconnected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1494\" data-end=\"1525\"\u003e\n\u003ctd data-start=\"1494\" data-end=\"1511\" data-col-size=\"sm\"\u003eSystem voltage\u003c\/td\u003e\n\u003ctd data-start=\"1511\" data-end=\"1525\" data-col-size=\"sm\"\u003e12V or 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1526\" data-end=\"1574\"\u003e\n\u003ctd data-start=\"1526\" data-end=\"1556\" data-col-size=\"sm\"\u003eFull-load temperature range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1556\" data-end=\"1574\"\u003e-40°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1575\" data-end=\"1627\"\u003e\n\u003ctd data-start=\"1575\" data-end=\"1600\" data-col-size=\"sm\"\u003eElectronics protection\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1600\" data-end=\"1627\"\u003eIP67 potted electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1628\" data-end=\"1660\"\u003e\n\u003ctd data-start=\"1628\" data-end=\"1652\" data-col-size=\"sm\"\u003eConnection protection\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1652\" data-end=\"1660\"\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"1662\" data-end=\"1699\"\u003e \u003c\/p\u003e\n\u003ch3 data-section-id=\"purqi0\" data-start=\"1701\" data-end=\"1718\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp data-start=\"1720\" data-end=\"1822\"\u003eFor correctly designed 12V or 24V DC load circuits within the continuous rating of the selected model.\u003c\/p\u003e\n\u003ch3 data-section-id=\"6zii9o\" data-start=\"1824\" data-end=\"1849\"\u003eFitment \/ Wiring Note\u003c\/h3\u003e\n\u003cp data-start=\"1851\" data-end=\"2209\"\u003eThe BatteryProtect is unidirectional and must be connected with current flowing from \u003cstrong data-start=\"1936\" data-end=\"1949\"\u003eIN to OUT\u003c\/strong\u003e. Do not connect an inverter or inverter\/charger through its main DC terminals; use the BatteryProtect to control the appliance’s remote on\/off input instead. Correct cable sizing and external fuse protection are required. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"14lzghq\" data-start=\"2211\" data-end=\"2230\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul data-start=\"2232\" data-end=\"2297\"\u003e\n\u003cli data-section-id=\"12gkgev\" data-start=\"2232\" data-end=\"2297\"\u003eVictron BatteryProtect in the selected 65A, 100A or 220A rating\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"65A","offer_id":54323481313621,"sku":"VE-BPR65","price":34.95,"currency_code":"GBP","in_stock":true},{"title":"100A","offer_id":54323481346389,"sku":"VE-BPR100","price":44.95,"currency_code":"GBP","in_stock":true},{"title":"220A","offer_id":54323481379157,"sku":"VE-BPR220","price":79.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0944\/8004\/0277\/files\/1572956994_24603600.png?v=1783517329","url":"https:\/\/relivecampers.co.uk\/products\/victron-batteryprotect-12-24v","provider":"Relive Campers LTD","version":"1.0","type":"link"}